Recommended Architectures for Data Centres

 
 

Value proposition


Main drivers

  • Since designing, installing and maintaining a Data Centre installation is complex and hazardous, it requires mastery of architectures, products and service offers, from the early preliminary design to operations.
  • Business continuity to secure and increase revenues, since downtime outages are huge.
  • Operational efficiency : for ROI of the infrastructure
  • Evolutivity : Site ability to follow high rate evolution on IT technologies

Solution in brief
  • IEC "End to end power solutions for Data Centres" consist of a consistent library of recommended architectures, for different levels of power sizing and redundancy level.
  • A recommended architecture is defined by its electrical diagram, the definition of equipment, the maintenance requirements, from utility feeder down to critical loads.
  • These architectures are fully qualified, with dependability engineering and simulations on: Availability, reliability, investment and operational costs.

Value proposition 
  • Peace of mind: High availability solutions, consistent, with field experience embedded. Homogeneous across the complete power system, from utility feeder down to critical loads. Compliance with Uptime Institute's TIER classification.
  • Business continuity / disaster recovery: Critical info delivered to right person at the right time
  • Qualified solutions: the solutions offer a range of 4 x levels of redundancy (based on TIER recommendation), with availability values from 99,993 to 99,99999996 %, and estimates of Total Cost of Ownership (to help in selecting the best alternative considering customer needs), evolutivity without shutdown.

Differentiation factors

  • These solutions are consistent, with field experience embedded. As the strength is that of the weakest link, they proposed a homogeneous solution across the complete power system .
  • They fully integrate measure & monitoring for risk management and traceability .
  • Pre-engineered solutions allow for improved performances, more engineering and studies than one-shot projects .
 

Architecture

Architecture
 

Main Energy Efficiency characteristics

  • Energy availability: dependability study (statistical values for reliability and availability)

  • Energy savings: "End to end power solutions for Data Centres" integrate energy metering in key equipment, in order to provide facility managers with guidelines for potential savings.

  • Environmental impact: Equipment selection is optimised for major performance and limitation of environmental impact (reduced losses, copper section, plastic quantities, etc.)
 
 
 
 
 

Solution breakdown


Services

  • Maintenance requirements

Components

  • MV switchboard for utility, distribution, ring substation
  • MV or LV gensets recommendations
  • Dry MV/LV transformers
  • LV switchboards: for the supply of critical, important and non-critical loads
  • UPS systems: for IT loads and some CRAC elements
  • Connections: busways or cables
  • iFlexPower for IT rooms
  • Electrical Power monitoring
  • Electrical Power automation
  • Link to BMS